Issue number: 1
Lights not flat to the ceiling
Issue number: 2
Gap between tiles and ceiling
Issue number: 3
Radiator pipe covers not fitted correctly
Issue number: 4
Radiator brackets fitted upside down
Issue number: 5
Poor finish to silicon.
Shower screen screws caps missing
Issue number: 6
Poor finish to silicon
Issue number: 7
Paint on wall tiles, poor finish between tiles and ceiling
Issue number: 8
As above
Issue number: 9
Poor decorating finish to door lining and architrave
Issue number: 10
Silicon poorly applied/missing between walls and floor by toilet
Issue number: 11
Paint on fan, fan noisy
Issue number: 12
Poor finish to exterior silicon, head of screw visible. Both sides
Issue number: 13
Poorly applied silicon around window
Issue number: 14
Damage to window frame and gasket
Issue number: 15
Head of window reveal not level
Issue number: 16
Window board has been fitted 2nd fix, should be done 1st fix
Issue number: 17
No bulnose to the window board end
Issue number: 18
Poor paint finish to window board
Issue number: 19
Rad pipes not painted and no wall caps fitted
2 number
Issue number: 20
Skirting poorly patched
Issue number: 21
pencil marks on wall
Issue number: 22
Incorrect light fight for ceiling position
Issue number: 23
Paint on socket
Issue number: 24
Paint on socket screw cap missing
Issue number: 25
Paint on light switch and screw cap missing
Issue number: 26
Bad joint between ceiling and wall, plasterboard too short
Issue number: 27
En-suite door, privicy lock not working, paint on handle
Issue number: 28
Architrave mitres not glued or nailed
Issue number: 29
Ceiling needs another coat of paint
Issue number: 30
Poor paint finish to both door linings
Issue number: 31
Eaves doors, edges poorly finished, paint on hinges, hinges loose and no stop on the bottom
Issue number: 32
Bedroom door sticks at the top


Issue number: 33
No insulation to pipes


Issue number: 34
Double trim has had a large notch taken out for the fan extractor, check with structral engineer.


Issue number: 35
Specification not clear regarding insulation.
Some dwarf walls have no insulation, some have fibreglass insulation and some have celitex insulation.
The roof has insulation between the rafters apart from in front of the dorma this is missing.
Normally needs insulation under the rafters to stop cold bridging.
If these areas are not warm areas, the eave doors need upgrading, to include insulation, latches and stops all round


Issue number: 36


Issue number: 37


Issue number: 38
Front sectionof flooring not fixed


Issue number: 39
Incorrect stirting finish, poor paint work


Issue number: 40
Incorrect stirting finish, poor paint finish


Issue number: 41
Paint on spindles


Issue number: 42
Poor finish stair string to wall


Issue number: 43
Movement crack at the cieling wall joint


Issue number: 44
Paint on light switch, screw cap missing


Issue number: 45
Poor paint finish onthe door and door lining



Issue number: 46
Wall to the right of the stairs, poor finish uneven plaster finish


Issue number: 47
Towel rad brackets upside down


Issue number: 48
Excess silicon in corner


Issue number: 49
Toilet seat in the wrong position


Issue number: 50
Vanity unit draws need adjustment


Issue number: 51
Silicon at the end of bath missing


Issue number: 52
Bath over flow not in the right position


Issue number: 53
Shower loose


Issue number: 54
Sliding door not operating correctly, not square on the frame and has been damaged at same time


Issue number: 55
Paint on handle and lock


Issue number: 56
Paint on lock keep, poor paint finish on door lining


Issue number: 57
Incomplete finish between tile and door lining


Issue number: 58
Paint on tiles


Issue number: 59
Paint on light switch, screw caps missing



Issue number: 60
Paint on socket. screw caps missing


Issue number: 61
Paint on switch


Issue number: 62
Paint on fan isolater,screw caps missing


Issue number: 63
missing newel post cap


Issue number: 64
Pen on room thermosatic


Issue number: 65
Paint on bathroom door handle


Issue number: 66
Damage to door front


Issue number: 67
Ridge in floor by rear bed doors


Issue number: 68


Issue number: 69
Excessive gap to cupboard door and lining.
Door doesn't latch


Issue number: 70
Gap between architrave not parellel


Issue number: 71
paint on spindles



Issue number: 72
Poor paint finish on the woodwork



Issue number: 73


Issue number: 74


Issue number: 75
Poor paint finish on walls and ceiling


Issue number: 76


Issue number: 77



Issue number: 78
Window board fitted as 2nd and not 1st fix capentry,
Poor paint finish


Issue number: 79
Left hand window reveal out of square by 25mm



Issue number: 80
Poorly applied silicon around the window


Issue number: 81
Radiator pipes not painted and pipe caps not fitted



Issue number: 82
Light switch behind the radiator



Issue number: 83
Door does not latch



Issue number: 84
Door lining not fitted correctly, head of lining and side have moved apart


Issue number: 85
Intermittent strip missing



Issue number: 86
Architrave mitres not lined up


Issue number: 87
Paint on socket


Issue number: 88
Paint on socket, screw caps missing


Issue number: 89
Poor finish to woodwork


Issue number: 90



Issue number: 91
Poorly applied silicon around the window



Issue number: 92
Window board fitted 2nd fix instead of 1st fix carpentry


Issue number: 93
Radiator pipes not painted and pipe caps not fitted


Issue number: 94
Window head reveal not level



Issue number: 95
Paint on sockets and screw caps missing X 4


Issue number: 96
Lights nositting flat to the ceiling, gaps around lights


Issue number: 97
Cracks in the ceiling


Issue number: 98
Large gap behind back of the architrave


Issue number: 99
Excess silicon left hand side of vanity unit


Issue number: 100
Slight damage to right side of vanity unit


Issue number: 101
Draws need adjustment


Issue number: 102
Toilet seat loose and not in the right position


Issue number: 103
Tap loose


Issue number: 104
Shower valve control pround of the wall


Issue number: 105
Hand spray bracket loose and proud of the wall


Issue number: 106
Towel radiator brackets fitted upside down


Issue number: 107
Towel radiator pipes not painted and pipe caps missing


Issue number: 108
Silicon missing on the front of the shower tray


Issue number: 109
Silicon missing around the base of the door lining, both sides


Issue number: 110


Issue number: 111
Paint on shower outlet and on wall tiles


Issue number: 112
Width of door lining has been extended


Issue number: 113
Poor cut out for door hinges


Issue number: 114
Uneven/ excessive gap between door and door lining


Issue number: 115
Screws missing from latch


Issue number: 116
Poor decorative finish


Issue number: 117


Issue number: 118
Paint on light switch/ missing screw caps


Issue number: 119
Paint on light switch/ screw caps missing


Issue number: 120
Paint on socket, screw caps missing


Issue number: 121


Issue number: 122
Paint on fan isolaterand missing screw cap


Issue number: 123
Radiator pipes not painted and missing caps


Issue number: 124
Skirting missing between architrave and wall


Issue number: 125
Door stop missing


Issue number: 126
Poorly applied silicon around window


Issue number: 127
Window board fitted post plastering, decorating poor


Issue number: 128
Poor finish to the wood work


Issue number: 129


Issue number: 130
Poor decorative finish to the ceiling


Issue number: 131


Issue number: 132
Back wall not plastered.
Soil pipe not boxed in


Issue number: 133
Expanded foam round pipes and waste just left unfinished


Issue number: 134
No pipe insulation


Issue number: 135
Wire left hanging and stretched across pipes, should be clipped back


Issue number: 136
Waste pipe left unsupported


Issue number: 137
Paint on clynder


Issue number: 138
Poor decorative finish, gaps round ceiling, in corners by door linng.


Issue number: 139


Issue number: 140


Issue number: 141


Issue number: 142


Issue number: 143
Finish to skirting board


Issue number: 144
String to wall poor joint thick filler


Issue number: 145
Damge to stair string


Issue number: 146
Base of newel post, poor finish


Issue number: 147
Poor finish to underside of handrail, paint on spindles


Issue number: 148
Base rail does not line up or overhang the plaster unstand of the stair well, top section has been made up with filler, filled at an angle


Issue number: 149
As above


Issue number: 150
Newel cap missing


Issue number: 151
Poorly applied silicon around the front, no security chain on the door


Issue number: 152
Cover trim between door and sidelight, poorly fitted, excess silicon on it


Issue number: 153
Paint on switch, screw caps missing


Issue number: 154
Paint on switch


Issue number: 155
Paint on switch


Issue number: 156
Paint on socket, screw caps missing


Issue number: 157
Paint on light fitting


Issue number: 158
Boxin by kitchen wall, has no skirting fitted and is painted with emulsion, should be stain wood


Issue number: 159
Utility door frame, nmber of nails have not been punched in.
Paint work poor


Issue number: 160


Issue number: 161
Newel cap missing


Issue number: 162
Door latch proud


Issue number: 163
Uneven window margins, poorly applied silicon


Issue number: 164
Paint on sockets,


Issue number: 165
Window board poorly fitted and docorated


Issue number: 166
Oversize cut out for the hinges


Issue number: 167
Poor decorative finish


Issue number: 168
As above


Issue number: 169
As above


Issue number: 170


Issue number: 171



Issue number: 172



Issue number: 173



Issue number: 174


Issue number: 175



Issue number: 176


Issue number: 177



Issue number: 178
Dish washer door rubs on the worktop


Issue number: 179
Jubile clip required on dish washer waste


Issue number: 180
ole in base of sink unit, items could full down


Issue number: 181
Doors do not line up with each other


Issue number: 182
Paint on door


Issue number: 183
Draw not line up


Issue number: 184
Shelvs not fitted


Issue number: 185


Issue number: 186
Fridge retaining bracket, not fitted correctly


Issue number: 187
Protective film over door edges and end panels


Issue number: 188
Hod not fixed down, or siliconed in


Issue number: 189
Cooker hod chimney section not fitted back to the wall


Issue number: 190
Oven no secured in place


Issue number: 191
Shelves missing


Issue number: 192
Shelves missing



Issue number: 193
Very poorly cut mitres to the pelmit



Issue number: 194



Issue number: 195


Issue number: 196
Plinth not fitted flush, the two pieces should be joined together


Issue number: 197
Paint on the doors.
Doors won't open, so could not check if they work okay



Issue number: 198
Skirting board not sitting correctly


Issue number: 199
Poor paint finish to woodwork


Issue number: 200


Issue number: 201


Issue number: 202



Issue number: 203


Issue number: 204
Excessive gap to door and door lining


Issue number: 205
Paint on switch


Issue number: 206
Socket buried in the plaster


Issue number: 207
Poor decorative finish to ceiling, around
Boxin
Lights
Smoke alarm


Issue number: 208


Issue number: 209


Issue number: 210


Issue number: 211
Tap Loose


Issue number: 212
Toilet seat in wrong position


Issue number: 213
Fan sitting proud of the wall


Issue number: 214
Silicon missing from around the basin


Issue number: 215
Pencil marks on the wall


Issue number: 216
Poor finish to the paint on the woodwork
Nails not punched in


Issue number: 217
Poor mitre cut


Issue number: 218
Paint and silicon on switch, screw cap missing


Issue number: 219
Paint on socket.screw caps missing
No low level socket for the washing machine


Issue number: 220
Towel radiator brackets upside down


Issue number: 221
Raise area on the floor, out of level. This will restrict where the washing machine will be able to go


Issue number: 222
The top half of the walls are not plasterboarded, it looks like tile backer board, this is not suitable for decorating


Issue number: 223
As above


Issue number: 224
Rough cut out of architrave around tiles


Issue number: 225
Door lining too narrow, additional strips of timber have added to allow for tiles.
Now leaves a big gap behind the architrave above the tiling


Issue number: 226
As above


Issue number: 227
Architrave poorly fitted to both side of the W/C door. Some of the architrave is loose


Issue number: 228
As above


Issue number: 229
Light fitting broken


Issue number: 230
Intermittent strip missing


Issue number: 231


Issue number: 232
Mortar staines on brickwork


Issue number: 233
Mortar colour variation on brickwork between the two doors


Issue number: 234
Mortar stains to brickwork


Issue number: 235
As above


Issue number: 236
Gap between K-render bead and brickwork


Issue number: 237
Window cill short forbrick opening


Issue number: 238
No disable access


Issue number: 239
Marks on the front door


Issue number: 240
Downpipe short of gulley, missing pipe bracket.
Pipe has been screwed together at the last joint, this is wrong


Issue number: 241
Wiring incomplete in meter box


Issue number: 242
No mastic around around boxes


Issue number: 243
K-render damaged to the side of the gas box.
No gas connected, why has the box be fitted


Issue number: 244
No latch on gate, hinges too small for gate


Issue number: 245
White stains on brickwork under window


Issue number: 246
Downpipe too short for the gulley, missing a pipe bracket


Issue number: 247
Mark/ stains to corner of quion stones


Issue number: 248
Nails left in fence


Issue number: 249
Timber left fixed to the fence


Issue number: 250
Garden has not been prepared or tufted