Mr. & Mrs Jones

428 Farnham Rd, Slough SL2 1HZ

Report by: Nigel Methven
Report date: 11th Febuary 2026

Issue number: 1

Bathroom

Tiles do not fully line up

Issue number: 2

Bathroom

Tile bead butted together, should be mitred

Issue number: 3

Bathroom

Tile bead to corner not flush with the tiles

Issue number: 4

Bathroom

Extremely rough edge to the door

Issue number: 5

Bathroom

Door won't close, catches on the bottom

Issue number: 6

Bathroom

Door keep has not been let into the door lining

Issue number: 7

Bathroom

Door lining is too near for the width of the wall
Poor paint finish to th woodwork

Issue number: 8

Bathroom

Rough cut out for the hinges

Issue number: 9

Stairs

New wall constructed to the stairs, new wall overhangs the stair string, aprin and newel post but no timber trim have been fitted, leaving the rough edge exposed.
No handle rail fitted

Issue number: 10

Stairs

Plasterboard screws are popping the plaster

Issue number: 11

Stairs

Wall at the base of the stairs are rough, where the old newel has been built into the new wall.
The corner of thenew wall is not plumb and even

Issue number: 12

Utility room

Door fitted upside down

Issue number: 13

Utility room

Architrave incomplete, architrave already fitted poorly cut

Issue number: 14

Utility room

Rough cut out for door hinge.

Paint on door

Issue number: 15

Utility room

Door lining incorrectly constructed out of different width timber

Issue number: 16

Utility room

Rough cut out for latch keep.

Ironmongery does not match

Issue number: 17

Utility room

Plaster work both side of the door way, poorly finish, uneven angles, corners not plumb and corners rounded off

Issue number: 18

Utility room

Paintwork poor, image shows sticker still on the timber and painted over

Issue number: 19

Utility room

Rough tile cuts around doorway

Issue number: 20

Utility room

As above

Issue number: 21

Utility room

No isolator switch fiited to appliances
No extractor fan fitted

Issue number: 22

Hallway

Rough tile cuts around radiator pipes
Signs that the radiator leaks

Issue number: 23

Hallway

Lounge door fitted upside down.

Issue number: 24

Hallway

Meter cupboard built to a very poor standard,
Sides made up of a number of pieces
Top has been cut incorrectly and two small have been glued inplace to repair
Door hung with the wrong hinges and fitted with no catchs or handles.
In parts need sanding down

Issue number: 25

Hallway

Electrical cables left hanging, shoud be chase in the wall or fitted inelectrical ducting

Issue number: 26

Hallway

Cables around the consumer unit need to be clipped back to the wall.
Exposed cable should be fitted in a junction box

Issue number: 27

Lounge

Door poor fitted, uneven gaps between door and lining.
Paint on door
Door rattles due to thedoor stops not being refitted to suit new door

Issue number: 28

Lounge

Rough cut out for latch keep.
Ironmongery does not match

Issue number: 29

Lounge

Rough cut out for door inge

Issue number: 30

Shower room

Door has been fitted upside down.
The door handle is not parrallel to the door edge
Paint on the door

Issue number: 31

Shower room

Rough cut out for latch keep

Issue number: 32

Shower room

Architrave are poorly fitted, not all nails have been driven inbelow the surface.
Internal architrave have been fitted the wrong way round

Issue number: 33

Shower room

As above

Issue number: 34

Shower room

Shower value has been damaged.
Shower supply pipe covers are loose and not siliconed

Issue number: 35

Shower room

Stray has not been siliconed

Issue number: 36

Shower room

Door loose and has not been silicon.
Width needs adjustment, head is loose and out of level

Issue number: 37

Shower room

Poorly applied silicon. Silicon is smugged over the tiles

Issue number: 38

Shower room

There are some area of grout are not full or flush

Issue number: 39

Shower room

Client informs me the toilet is connected to hot water supply

Issue number: 40

Kitchen

Rough tile cuts around radiator pipes

Issue number: 41

Kitchen

Poor decoration generally, some area of the walls appear to have no more then a miscoat applied
Woodwork need an additional sand down and repainted

Issue number: 42

Kitchen

Upstand to roof light has been left unfinished, no trim or plster stop fitted

Issue number: 43

Kitchen

Paint and silicon on the head of the bi-fold doors

Issue number: 44

Kitchen

Head of door opening not level

Issue number: 45

Kitchen

Bi=fold set too high above the floor

Issue number: 46

Kitchen

Trickle vent broken

Issue number: 47

Kitchen

Small section of glass gasket missing

Issue number: 48

Kitchen

Poor finish around the switch and uneven plaster below

Issue number: 49

Kitchen

Floor tiling not set out correctly, cut tile ending up in the middle of the pening

Issue number: 50

Kitchen

Reveals of the kitchen opening out of square

Issue number: 51

Kitchen

Floor not level, from the kitchento the lounge

Issue number: 52

Kitchen

Remians of grout left on the floor tiles

Issue number: 53

Exterior

Patchy finish to the k-render on the first floor

Issue number: 54

Exterior

Damage to k-render behind the downpipe

Issue number: 55

Exterior

Render stains on the guttering and fascia

Issue number: 56

Exterior

Offset bends missing to the downpipe

Issue number: 57

Exterior

K-render has been taken down to ground level, this will now bridge the DPC

Issue number: 58

Exterior

Protective film on the bi-fold doors

Issue number: 59

Exterior

Exposed cables

Issue number: 60

Exterior

End cap to door cill loose

Issue number: 61

Exterior

Boundary wall not rendered

Issue number: 62

Exterior

Flat roof flashing too low, should be at least 100mm

Issue number: 63

Exterior

Top coat of roofing patchy

Issue number: 64

Exterior

Old guttering left on the roof