Mr.& Mrs Jaume

36 Pennington Drive Weybridge KT13 9RU

Report by: Nigel Methven
Report date: 19th Decmeber 2025

Issue number: 1

Exterior left elevation

Mortor missing from verge tile

Issue number: 2

Exterior

Shold there be a cover to corner profile

Issue number: 3

Exterior left elevation

Nail sticking out of brickwork

Issue number: 4

Left elevation

Air vent missing

Issue number: 5

Left elevation

Waste pipe not fitted parallel with the wall

Issue number: 6

Left elevation

gap around waste pipe

Issue number: 7

Left elevation

Hole in boss pipe, allowing raw sewage to leak agianst the wall

Issue number: 8

Left elevation

Making good around waste pie in non-matching mortor

Issue number: 9

Left elevation

Rain water pipe short of the gulley

Issue number: 10

Left elevation

Mortor sraines on the brickwork

Issue number: 11

Left elevation

As above

Issue number: 12

rear elevation

Large gap between door cill and brickwork

Issue number: 13

Rear elevation

No lamps in light fitting

Issue number: 14

Rear elevation

Brickwork short of patio doors, gap made up with mortor.
Small section of brick on edge bricks on show

Issue number: 15

Rear elevation

Pointing around door cill, not fully bonded to surrounding bricks and colour match poor

Issue number: 16

Rear elevation

Poorly fitted weep holes

Issue number: 17

Rear elevation

Damaged brick against patio door

Issue number: 18

Rear elevation

Concrete slab protuding in front of patio doors

Issue number: 19

Rear elevation

Pointing missing from copping stones

Issue number: 20

Rear elevation

DPC not high enough to be 150mm above finished ground level

Issue number: 21

Rear elevation

Rain water gulley too far from the wall

Issue number: 22

Rear elevation

Pointing required to fill empty mortor joints

Issue number: 23

Rear elevation

Rain water pipe discharges irectly onto the ground, no gulley visible

Issue number: 24

Rear elevation

Grill missing from gulley

Issue number: 25

Rear elevation

Soil pipe has no rodding access and brickwork around pipe enterer needs to be improved

Issue number: 26

Rear elevation

Outside taps not level

Issue number: 27

Rear elevation

Open sewer pipe

Issue number: 28

Rear elevation

No bird cage on soil pipe

Issue number: 29

Side elevation

Manhole cover not fixed down

Issue number: 30

Side elevation

Holes in wall.

Issue number: 31

Side elevation

Cladding does not sit flat agianst the wall

Issue number: 32

Side elevation

Gap at meeting point of the soffit on the gable

Issue number: 33

Side elevation

Soil pipe too short, should be 900mm above opening window, no bird cage fiited

Issue number: 34

Side elevation

Waste pipe are not parallel with the house

Issue number: 35

Side elevation

No rodding access point fitted to soil pipe

Issue number: 36

Side elevation

Waste pipe not parallel to the house. Wall tie sticking out of brickwork

Issue number: 37

Side elevation

3 Fascia caps missing

Issue number: 38

Front elevation

Water damage to soffit board,

Issue number: 39

Front elevation

Gulley grill demaged

Issue number: 40

Front elevation

Support post missing

Issue number: 41

Front elevation

Fascia joint cover missing

Issue number: 42

Front elevation

Manhole cover not fixed

Issue number: 43

Front elevation

Brickwork on both side of the front door, incorrectly bonded, mortor colour poor match, generally poor finish to brickwork

Issue number: 44

Front elevation

No mortor in bed joints under front door

Issue number: 45

Front elevation

Brickwork not fully bonded

Issue number: 46

Front elevation

Cut bricks over front door not fully pointed

Issue number: 47

Front elevation

Holes in brickwork, silicon on bricks

Issue number: 48

Front elevation

Inspect screen not fitted correctly.
(this is visible on all elevations)

Issue number: 49

Front elevation

Gable end of porch roof butted against cladding, should be cladding butted against gable end

Issue number: 50

Front elevation

Top of shutters bend at the top, need a spacer to keep the flat

Issue number: 51

Front elevation

No silicon joint below windows

Issue number: 52

Exterior

Top section of cladding has uneven gap between cladding and soffit.
Is this a poor cut or should there be a trim fitted

Issue number: 53

Exterior

As above

Issue number: 54

Exterior

As above

Issue number: 55

Garage

Floor incomplete

Issue number: 56

Garage

Rear floor needs completing

Issue number: 57

Garage

Discharge pipes from the boiler, discharged into pipe with no reducer fitted, or trap fitted. This will allow odour from drains to escape

Issue number: 58

Garage

Insulation and fire proofing incomplete on the ceiling

Issue number: 59

Garage

Insulation and fire proofing incomplete on the walls

Issue number: 60

Garage

No restraining strap visible

Issue number: 61

Garage

No connection visible between timber trimmer and steel post.

Issue number: 62

Kitchen

Grout missing around door lining

Issue number: 63

Kitchen

Architrave needs an addition sand

Issue number: 64

Kitchen

Slots on roof light upstand

Issue number: 65

Kitchen

No shadow line on top of media unit

Issue number: 66

Kitchen

Cornice missing from media unit

Issue number: 67

Kitchen

Loose handle draw not lined up

Issue number: 68

Kitchen

Draws on the island do not line up and do not sit flash when closed

Issue number: 69

Kitchen

Grout missing by patio door

Issue number: 70

Kitchen

Doulbe doors into lounge, top bolt does not line up with bolt keep and bottom bolt has no keep or hole to engage with

Issue number: 71

Kitchen

Skirting needs to resanded

Issue number: 72

Kitchen

Paint on hinge on double doors

Issue number: 73

Kitchen

Internal curcass of larder cupboard does not match

Issue number: 74

Kitchen

Series of holes above fridge, needs filling and decorating

Issue number: 75

Kitchen

Dor not lining up

Issue number: 76

Kitchen

Hole in wall at the rear of the sink unit

Issue number: 77

Kitchen

Draw runners on large draws seem to struggle with the wieght

Issue number: 78

Kitchen

Door loose

Issue number: 79

Kitchen

Handle missing

Issue number: 80

Kitchen

Hand spray loose

Issue number: 81

Kitchen

Door do not line up

Issue number: 82

utiliy room

Tap loose

Issue number: 83

Utility

Doors do not line up

Issue number: 84

Utility room

As above

Issue number: 85

Utility room

Poor decorating finish between units and wall left hand side

Issue number: 86

Lounge

Stain on french windows

Issue number: 87

Lounge

Gaps in floor by french windows

Issue number: 88

Lounge

Skirting missing

Issue number: 89

Lounge

Skirting needs to be resanded

Issue number: 90

Lounge

Architrave not parallel to the wall

Issue number: 91

Hallway

Cupboard doors do not line up

Issue number: 92

Hallway

Cornice mising from top of cupboard

Issue number: 93

Stairs

Newel cap roungh on one side X 3

Issue number: 94

Landing

As above

Issue number: 95

Landing

Plasterboard screw popping out

Issue number: 96

Landing

Architrave needs to be resanded

Issue number: 97

Landing

Squeaky floor top of the stairs

Issue number: 98

Landing cupboard

Latch keep not flush with the lining

Issue number: 99

Loft

Access was restricted a full inspection was not possible

Issue number: 100

Loft

Light not working

Issue number: 101

Loft

Insulation had been moved to install extractor fan and not replace.
Ducting to extactor not insulated

Issue number: 102

Main bathroom

Privicy latch not working

Issue number: 103

Main bathroom

Sensor not fitted correctly

Issue number: 104

Main bathroom

Bath panel not fully fitted

Issue number: 105

Main bathroom

Grout missing by bath filler

Issue number: 106

Main bathroom

Heating pipe to radiator need painting and wall cap fitted

Issue number: 107

Main bathroom

Marks on window frame

Issue number: 108

Main bathroom

Gap between wall and vanity unit

Issue number: 109

Middle bedroom

Skirting and architrave need to be resanded

Issue number: 110

Middle bedroom

Back of wardrope loose

Issue number: 111

Midlle bedroom

Top and bottom fitted the wrong way round mean the fixings are all visible

Issue number: 112

Middle bedroom

Asabvoe

Issue number: 113

Middle bedroom

Poor finish to boxin above wardropes

Issue number: 114

Middle bedroom

Large shrinkage crack between infil panels, door do not line up

Issue number: 115

Midle bedroom

Soft close hinges not fitted to two doors

Issue number: 116

Middle bedroom

Sqeaky floor by the door

Issue number: 117

Master en-suite

Silicon missing behind the basin

Issue number: 118

Master en-suite

Gap between wall and tiles behind toilet

Issue number: 119

Master en-suite

As above

Issue number: 120

Master en-suite

Gap between tiles and wall behind basin

Issue number: 121

Master en-suite

Paint missing by loo roll holder

Issue number: 122

Master en-suite

Plasterboard screw starting to pop out

Issue number: 123

Master en-suite

Gap between shower srceen and skirting board

Issue number: 124

Master bed

Ceiling out of level by 25mm

Issue number: 125

Master bed

Ridge in floor from existing house to extension

Issue number: 126

Master bed

Door does not close properly

Issue number: 127

Master bed

Architrave needs to be re-sanded

Issue number: 128

Master bed

Poor finish between wall and wardropes

Issue number: 129

Flat roof area

Pointing missing to copping stones

Issue number: 130

Flat roof area

Trim around window not fully fitted

Issue number: 131

Flat roof area

Excessive gap between cladding and soffit

Issue number: 132

Main roof

Two tiles missing at the bottom of the valley

Issue number: 133

Flat roof area

Uneven gap between soffit and window/wall

Issue number: 134

Flat roof area

Poor corner finish

Issue number: 135

Main roof

Area above flat roof, nails not fully driven home, corner cap missing from fascia

Issue number: 136

Flat roof area

Soffit nail not driven home, poly cap has come off

Issue number: 137

Bathroom window

Soffit above window not level

Issue number: 138

Front bed

Skirting/ architrave needs to be re-sanded

Issue number: 139

Front bed en-suite

Stain ceiling

Issue number: 140

Front bed en-suite

Poor finish to skirting against the wall tiles

Issue number: 141

Office

Paint on floor

Issue number: 142

Office

Stirting and architrave needs to re-sanded

Issue number: 143

Ground floor W/C

Grout missing around door lining

Issue number: 144

Ground floor W/C

Screw missing from hinge

Issue number: 145

Ground floor W/C

Silicon missing from between worktop and splash back and on top of splash back

Issue number: 146

Ground floor W/C

Wall lights missing, ceiling light needs to fitted

Issue number: 147

Playroom

Cable in cupboard need to be clipped and tided up. Cover fitted alarm bx

Issue number: 148

Playroom

Under stair of stair in cupboard needs to be plasterboarded and decorated.

Issue number: 149

Playroom

Door missing from understairs cupboard

Issue number: 150

Playroom

Pink paint from skirting on white architrave

Issue number: 151

Playroom

Door does not close