Issue number: 1
Paint on silicon between window board and window
Issue number: 2
Poor paint finish on window board
Issue number: 3
Paint on window
Issue number: 4
Door rattles when closed
Issue number: 5
Paint on sockey
Issue number: 6
Mark on ceiling
Issue number: 7
Top section of alcove architrave has been filled and painted, but not rubbed down before hand.
Issue number: 8
Silicon bedonding from top section of roof window
Issue number: 9
Poor finish to silicon around roof window
Issue number: 10
No depth to wall/ ceiling paint R/H side of dorma
Issue number: 11
Dwarf wall sligthly out of plumb, visible with architrave touches at the bottom and not the top
Issue number: 12
Rough edge to back of architrave L/H side
Issue number: 13
Mark to back edge of architrave L/H side
Issue number: 14
Pasterboard screw popping though
Issue number: 15
Stain on carpet in the corner by the radiator
Issue number: 16
Poor finish to paint on door stops L/H side
Issue number: 17
Remains of expanding form on window
Issue number: 18
Window dirty
Issue number: 19
Tap loose
Issue number: 20
Mark on radiator
Issue number: 21
Toilet seat loose
Issue number: 22
pencil marks on tiles
Issue number: 23
Toilet flush plate not sitting hard against the tiles
Issue number: 24
Silicon bead not taken the full lenght of the shower screen, leaving a 100mm gap
Issue number: 25
Glass packer left at the back of shower screen
Issue number: 26
Shower door very stiff, needs checking
Issue number: 27
R/H side of worktop edge un-finished, sharp edge
Issue number: 28
Shower hose outlet not siliconed back to the tiles
Issue number: 29
Bracket on newel post not being used
Issue number: 30
No finish to the top string between wall and newel post
Issue number: 31
Runs of paint on architrave inside the cupboard
Issue number: 32
Poor paint finish between wall and ceiling above PV control
Issue number: 33
Protective film on striking plate.
(image didn't come out)
Issue number: 34
Bottom newel post cap rough
Issue number: 35
Paint on newel cap
Issue number: 36
Dent in hand rail
Issue number: 37
Newel cap rough
Issue number: 38
Paint on the newel post cap.
Issue number: 39
Chip on stair newel cap
Issue number: 40
Visible gap between handrail and newel post
Issue number: 41
Paint on light switch
Issue number: 42
Un-even gap between architrave at junction of bed3-4
Issue number: 43
Top of architrave not in line, bed 3-4
Issue number: 44
Paint on switches
Issue number: 45
Not filled between architrave and wall
Issue number: 46
Gaps around door stops
Issue number: 47
Un-even gap between architrave bed 2 and bath
Issue number: 48
Tops of architrave not lining up
Bathrom and bedroom
Issue number: 49
Silicon debonding around window
Issue number: 50
Paint on window
Issue number: 51
Dirt on window
Issue number: 52
Socket not tight against the wall
Issue number: 53
TV cable cover out of level and not tight
Issue number: 54
Poor skirting detail against architrave R/H
Issue number: 55
Radiator pipe out of plumb
Issue number: 56
Chip on corner of skirting by door
Issue number: 57
Radiator pipe out out of plumb
Issue number: 58
Poor skirting detail against architrave L/H
Issue number: 59
Window appears to catch when opening, hard to be sure with the scaffold there
Issue number: 60
Paint on window
Issue number: 61
Dirty window
Issue number: 62
poor detail to skirting R/H side of the door
Issue number: 63
Protective film on latch
Issue number: 64
Paint on door
Issue number: 65
Silicon debonding from window
Issue number: 66
Paint on window
Issue number: 67
Protective film on door latch
Issue number: 68
Door very dirty, it look like just dust/dirt but needs checking once it's cleaned
Issue number: 69
Radiator pipe not plumb
Issue number: 70
Toilet not seating square
Issue number: 71
Window dirty
Issue number: 72
Tap loose
Issue number: 73
Draw on vanity unit catches when used
Issue number: 74
Mark on radiator
Issue number: 75
Protective film on latch
Issue number: 76
A lot of felix on the bath panel, may need a better frame
Issue number: 77
No silicon around the bath panel
Issue number: 78
Paint on striking plate
Issue number: 79
Paint on tiles
Issue number: 80
Shower outlet not siliconed back to the tiles
Issue number: 81
Paint on handrail x 2
Issue number: 82
Poor decorating finish around top of stairs to landing
Issue number: 83
Mark on nosing at 1st floor landing
Issue number: 84
Plasterbaord screws popping out. x 2
Issue number: 85
Un-even architrave gap between kichen and lounge door
Issue number: 86
Bottom cap missing from first floor newel post
Issue number: 87
Poor finish between flooring and skirting
Issue number: 88
Front door hieght, leaves no room for a door mat
Issue number: 89
Paint on window
Issue number: 90
Marks on handle
Issue number: 91
Paint not finished on underside of windowboard
Issue number: 92
Chip to corner of window reveal
Issue number: 93
Door binding on carpet
Issue number: 94
Small scratch to door
Issue number: 95
TV cable cover loose
Issue number: 96
Protective film still on latch
Issue number: 97
Poor decorative finish around striking plate
Issue number: 98
No sealant around pipe outlets
Issue number: 99
Basin not central
( just pointing this out, not a fault)
Issue number: 100
Flush plate not hard against the tiles
Issue number: 101
Tile trim covered in grout and cracking away from tiles
Issue number: 102
Window dirty
Issue number: 103
R/H side of architrave has been filled and painted, but not sanded to the correct shape first
Issue number: 104
Head of door nail holes to architrave not filled
Issue number: 105
Door rubs on flooring trim
Issue number: 106
Dirty window
Issue number: 107
Worktop not been siliconed
Issue number: 108
Cut out for boiler left rough
Issue number: 109
Bottom of boiler not fitted
Issue number: 110
Cover missing off downlight
Issue number: 111
Scratch to kitchen door
Issue number: 112
Paint on flooring
Issue number: 113
Fridge tap supplied, but no access to cupboard to plug in fridge
Issue number: 114
Paint on light switch
Issue number: 115
Paint on door
Issue number: 116
Poor finish to boxing
Issue number: 117
Cable left un-terminated
Issue number: 118
Poor siliconing around bi-fold doors, uneven and gaps
Issue number: 119
No finish between flooring and bi-folds
Issue number: 120
Plinths not fitted, sink unit inpieces
Issue number: 121
A number of shelves not fitted
Issue number: 122
Gap for washing mashine, but no waste or water supply
Issue number: 123
Meter box not siliconed to the wall
Issue number: 124
Downpipe missing, no car charger yet
Issue number: 125
Porch incomplete
Issue number: 126
Weep holes over front window don't match
Issue number: 127
Outside tap
Issue number: 128
Mortar staines to rear elevation
Issue number: 129
Boiler flue not fitted/finished correctly
Issue number: 130
Side expansion joint not fully mastic
Issue number: 131
Roof incomplete
Issue number: 132
Front window cill chipped
Issue number: 133
As above
Issue number: 134
Mortar staines to brickwork
Issue number: 135
Mortar stianes to soffit