Karla Eleni

Hay Cottage, Eastbourne Rd, South Godstone, RH9 8JQ

Report by: Nigel Methven
Report date: 9th March 2026

Issue number: 1

Kitchen

Work top joint not flat

Issue number: 2

Kitchen

Worktop splash back over hanging the units

Issue number: 3

Kitchen

Poor grout finsh between tiles

Issue number: 4

Kitchen

No end panel or plinth fitted to side of the unit

Issue number: 5

Kitchen

Plinth clip broken next to washing machine

Issue number: 6

Kitchen

Oven loose, not screwed back to the unit

Issue number: 7

Kitchen

Cooker hood retianing screws not fully tighten up.

Issue number: 8

Kitchen

Marks on paint work below cooker hood

Issue number: 9

Kitchen

Poor paint finish in rooflight well.

Issue number: 10

Kitchen

Hole in end panel

Issue number: 11

Kitchen

Cable for the under cupboard light, not fixed

Issue number: 12

Kitchen

Door rubs the door lining, latch catches the architrave

Issue number: 13

Lounge

Movement cracks below windows

Issue number: 14

Lounge

Protective film left on the window

Issue number: 15

Lounge

Opening section of bi-fold door, catches on the bottom

Issue number: 16

Lounge

Trickle vent has restrictive opening, catches the plaster

Issue number: 17

Kitchen and generally

Ironmongery does not match, hinges are brushed steel, latches are brass or dark metal and handles are black with brass screws

Issue number: 18

Front bedroom

Door does not close

Issue number: 19

Front bedroom

Damage to door edge

Issue number: 20

Front bedroom

Gaps along the top of the skirting against the wall

Issue number: 21

Front bedroom

Trickle vents missing from side window

Issue number: 22

Bathroom

Stains on bath, could be rust

Issue number: 23

Bathroom

As above

Issue number: 24

Bathroom

No shower screen.

Issue number: 25

Bathroom

No bath panel

Issue number: 26

Bathroom

No silicon on shower pipes.

Issue number: 27

Bathroom

Poor paint finish to pipes

Issue number: 28

Bathroom

As above

Issue number: 29

Bathroom

Cold tap loose

Issue number: 30

Bathroom

Fan stays on all the time. Should be on a timer

Issue number: 31

Bathroom

Mitres to architrave not fixed together.

Issue number: 32

Bathroom

Poor decorative finish to door lining, needs an additional sanding.

Issue number: 33

Bathroom

As above

Issue number: 34

Bathroom

Right hand side of the towel radiator, loose at the top

Issue number: 35

Bathroom

Handle and turn kob and latch and lock do not match

Issue number: 36

Hallway cupboard

Rough finish to heating manifold back board

Issue number: 37

Hallway cupboard

Stait prop, has not been painted.
Wedges left sticking out.
Areas not painted.
Sawn timber left exposed

Issue number: 38

Hallway cupboard

As above

Issue number: 39

Hallway cupboard

Expanded foam left around water main

Issue number: 40

Hallway cupboard

No architrave on inside of door lining

Issue number: 41

Hallway

Poor finish to packing of light switch by the front door.

Issue number: 42

Hallway

Fixing visible on kitchen door lining.

Issue number: 43

Hallway

Plaster board screws visible under string of stairs

Issue number: 44

Hallway

Plaster popping, caused by plasterboard screw not fully driven home

Issue number: 45

Halway

Cracking between cupboard door lining and wall

Issue number: 46

Stairs

Glue/ silicon to underside of handrail

Issue number: 47

Stairs

Wall paint appears to have been touched up, but is clearly visible

Issue number: 48

Stairs

Wood knot, has not been sealed and is showing through the paint

Issue number: 49

Stairs

Poor decorative finish to wall on the half landing

Issue number: 50

Stairs

Top section of wall, has had the paint touched up, but is clearly visible

Issue number: 51

Bedroom first floor

Poor finish to en-suite door lining

Issue number: 52

Bedroom first floor

Window protectors are loose, to both windows

Issue number: 53

Bedroom first floor

Poor paint finish to window protectors

Issue number: 54

Bedroom first floor

Movement crack at the base of the dorma roof

Issue number: 55

Bedroom first floor

As above

Issue number: 56

Bedroom first floor

Movement crack below the front window

Issue number: 57

Bedroom first floor

Damage to door lining below the hinge

Issue number: 58

En-suite

Noisey fan

Issue number: 59

En-suite

Standard basin trap fitted, should be chrome.

Issue number: 60

En-suite

Basin taps loose

Issue number: 61

En-suite

Privacy lock does not work

Issue number: 62

En-suite

Pipe caps missing

Issue number: 63

En-suite

Shower door handle loose on the inside

Issue number: 64

En-suite

Cable left exposed above the basin

Issue number: 65

En- suite

Latch and lock do not match

Issue number: 66

En-suite

Damage to door front

Issue number: 67

En-suite

Mark/ damage to basin support

Issue number: 68

En-suite

No silicon to back of shelf behind the toilet

Issue number: 69

En-suite

Shower head blocked, water only coming out of half the head

Issue number: 70

Loft

Door catches on the bottom

Issue number: 71

Loft

Key hole cover incomplete

Issue number: 72

Loft

Uneven gap around door

Issue number: 73

Loft

Insulation missing around extactor fan ducting

Issue number: 74

Loft

Restraining straps have not been fitted to the gable

Issue number: 75

Exterior

No mastic around meter boxes

Issue number: 76

Exterior

No bell or knocker to the front door

Issue number: 77

Exterior

Fascia and soffit and windows need to be cleaned

Issue number: 78

Exterior

As above

Issue number: 79

Exterior

As above

Issue number: 80

Exterior

Staining on concrete patio

Issue number: 81

Exterior

Paving has not been pointed

Issue number: 82

Exterior

Large gap below slates, large enough to allow insects in.

Issue number: 83

Exterior

Pointing below bi- fold doors in complete

Issue number: 84

Exterior

No insulation to garden tap

Issue number: 85

Exterior

Soft landscaping in complete

Issue number: 86

Exterior

As above

Issue number: 87

Exterior

Screws holding guttering together

Issue number: 88

Exterior

Rear guttering blocked, should be a hopper

Issue number: 89

Exterior

Lead flashng to roof above back guttering has not been pointed in.

Issue number: 90

Exterior

Box guttering is not fixed back to the wall, leaving a gap for water ingress.

Issue number: 91

Exterior

No security gate to back garden