Issue number: 1
Work top joint not flat
Issue number: 2
Worktop splash back over hanging the units
Issue number: 3
Poor grout finsh between tiles
Issue number: 4
No end panel or plinth fitted to side of the unit
Issue number: 5
Plinth clip broken next to washing machine
Issue number: 6
Oven loose, not screwed back to the unit
Issue number: 7
Cooker hood retianing screws not fully tighten up.
Issue number: 8
Marks on paint work below cooker hood
Issue number: 9
Poor paint finish in rooflight well.
Issue number: 10
Hole in end panel
Issue number: 11
Cable for the under cupboard light, not fixed
Issue number: 12
Door rubs the door lining, latch catches the architrave
Issue number: 13
Movement cracks below windows
Issue number: 14
Protective film left on the window
Issue number: 15
Opening section of bi-fold door, catches on the bottom
Issue number: 16
Trickle vent has restrictive opening, catches the plaster
Issue number: 17
Ironmongery does not match, hinges are brushed steel, latches are brass or dark metal and handles are black with brass screws
Issue number: 18
Door does not close
Issue number: 19
Damage to door edge
Issue number: 20
Gaps along the top of the skirting against the wall
Issue number: 21
Trickle vents missing from side window
Issue number: 22
Stains on bath, could be rust
Issue number: 23
As above
Issue number: 24
No shower screen.
Issue number: 25
No bath panel
Issue number: 26
No silicon on shower pipes.
Issue number: 27
Poor paint finish to pipes
Issue number: 28
As above
Issue number: 29
Cold tap loose
Issue number: 30
Fan stays on all the time. Should be on a timer
Issue number: 31
Mitres to architrave not fixed together.
Issue number: 32
Poor decorative finish to door lining, needs an additional sanding.
Issue number: 33
As above
Issue number: 34
Right hand side of the towel radiator, loose at the top
Issue number: 35
Handle and turn kob and latch and lock do not match
Issue number: 36
Rough finish to heating manifold back board
Issue number: 37
Stait prop, has not been painted.
Wedges left sticking out.
Areas not painted.
Sawn timber left exposed
Issue number: 38
As above
Issue number: 39
Expanded foam left around water main
Issue number: 40
No architrave on inside of door lining
Issue number: 41
Poor finish to packing of light switch by the front door.
Issue number: 42
Fixing visible on kitchen door lining.
Issue number: 43
Plaster board screws visible under string of stairs
Issue number: 44
Plaster popping, caused by plasterboard screw not fully driven home
Issue number: 45
Cracking between cupboard door lining and wall
Issue number: 46
Glue/ silicon to underside of handrail
Issue number: 47
Wall paint appears to have been touched up, but is clearly visible
Issue number: 48
Wood knot, has not been sealed and is showing through the paint
Issue number: 49
Poor decorative finish to wall on the half landing
Issue number: 50
Top section of wall, has had the paint touched up, but is clearly visible
Issue number: 51
Poor finish to en-suite door lining
Issue number: 52
Window protectors are loose, to both windows
Issue number: 53
Poor paint finish to window protectors
Issue number: 54
Movement crack at the base of the dorma roof
Issue number: 55
As above
Issue number: 56
Movement crack below the front window
Issue number: 57
Damage to door lining below the hinge
Issue number: 58
Noisey fan
Issue number: 59
Standard basin trap fitted, should be chrome.
Issue number: 60
Basin taps loose
Issue number: 61
Privacy lock does not work
Issue number: 62
Pipe caps missing
Issue number: 63
Shower door handle loose on the inside
Issue number: 64
Cable left exposed above the basin
Issue number: 65
Latch and lock do not match
Issue number: 66
Damage to door front
Issue number: 67
Mark/ damage to basin support
Issue number: 68
No silicon to back of shelf behind the toilet
Issue number: 69
Shower head blocked, water only coming out of half the head
Issue number: 70
Door catches on the bottom
Issue number: 71
Key hole cover incomplete
Issue number: 72
Uneven gap around door
Issue number: 73
Insulation missing around extactor fan ducting
Issue number: 74
Restraining straps have not been fitted to the gable
Issue number: 75
No mastic around meter boxes
Issue number: 76
No bell or knocker to the front door
Issue number: 77
Fascia and soffit and windows need to be cleaned
Issue number: 78
As above
Issue number: 79
As above
Issue number: 80
Staining on concrete patio
Issue number: 81
Paving has not been pointed
Issue number: 82
Large gap below slates, large enough to allow insects in.
Issue number: 83
Pointing below bi- fold doors in complete
Issue number: 84
No insulation to garden tap
Issue number: 85
Soft landscaping in complete
Issue number: 86
As above
Issue number: 87
Screws holding guttering together
Issue number: 88
Rear guttering blocked, should be a hopper
Issue number: 89
Lead flashng to roof above back guttering has not been pointed in.
Issue number: 90
Box guttering is not fixed back to the wall, leaving a gap for water ingress.
Issue number: 91
No security gate to back garden