Issue number: 1
Sink waste twisted
Issue number: 2
No siliicon between worktop and splash back
Issue number: 3
Cupboard door loose
Issue number: 4
Poor finish between wall and units
Issue number: 5
Protective film left on extractor unit
Issue number: 6
Poor finish to mitres above the hob
Issue number: 7
Issue number: 8
Freezer door not lining up with the housing unit
Issue number: 9
Fridge door does line up with the housing unit
Issue number: 10
Covers missing from freezer brackets
Issue number: 11
Cornice and boxing incomplete
Issue number: 12
End panel missing
Issue number: 13
Shelf lighting different colours
Issue number: 14
Cupboard lights should be on a sensor
Issue number: 15
Silicon missing to cupboard worktop
Issue number: 16
End panel incorrect width
Issue number: 17
Pre drill door fitted to pull out bin instead of a door blank
Issue number: 18
Loose inspection cover
Issue number: 19
Bottom of the downpipe missing a clip
Issue number: 20
Cables aroundair conditioning unit need to be clipped to the walll
Issue number: 21
Poor pointing to the underside of the coping stones
Issue number: 22
Issue number: 23
Issue number: 24
Issue number: 25
A number of bricks that have been used, are below standard and are missing face finish
Issue number: 26
Cable left sticking out
Issue number: 27
Hole in gulley grate
Issue number: 28
Images of mortar staines on the finished brickwork
Issue number: 29
Issue number: 30
Issue number: 31
Issue number: 32
Issue number: 33
Loose and damaged brick under kitchen window
Issue number: 34
Waste pipe not sealed around the wall
Issue number: 35
No cill to rear window
Issue number: 36
Poor finish to paving upstand
Issue number: 37
Ramp too high for turf level, mortar left at the edge stopping grass from growing
Issue number: 38
Builders debris left on lawn area
Issue number: 39
Paving uplights loose
Issue number: 40
Copping stones butted together at the corners, should be propose made corner stones or mitred
Issue number: 41
Boiler discharge pipe not sealed to the wall
Issue number: 42
Incorrect support for waste pipe
Issue number: 43
Waste pipe not sealed around
Issue number: 44
Poor finish to lead and pointing at the lower roof adbutment
Issue number: 45
Copping stone incorrectly laid
Issue number: 46
Cut tile not fixed/loose
Issue number: 47
No protection to top of exposed bricks at dog tooth feature. this will lead to frost/water damage over time
Issue number: 48
Flat roof lead starting to come out of the wall
Issue number: 49
As above
Issue number: 50
Images of the lead flashing around the flat roof, all to a poor finish
Issue number: 51
Issue number: 52
Issue number: 53
Downpipe laid across the roof, not secured
Issue number: 54
Dust coverleft on smoke alarm
Issue number: 55
No pipe covers fitted, pipes not painted, to both radiators
Issue number: 56
Issue number: 57
Architrave mitres to the utility room door do not line up correctly. Paint work finish poor
Issue number: 58
Architrave mitres to hall door door not line up
Issue number: 59
Double doors loose when closed, may rattle.
Issue number: 60
Paint on bolt keep
Issue number: 61
The head of the door lining has been increase in width the additional timber is still visible
Issue number: 62
Archittrave mitres to bedroom door do not line up
Issue number: 63
Paint on the cornice, ceiling has not been painted above units
Issue number: 64
Images below of the plaster finish, this is all to a poor standard, but the ceiling in the kitchen area is very poor
Issue number: 65
Issue number: 66
Issue number: 67
Issue number: 68
Intumescent strip missing from the door lining
Issue number: 69
Poor hinge cut out.
Paint on the hinge
Issue number: 70
Poor paint coverage to door and the lining
Issue number: 71
Section of skirting missing to door reveal
Issue number: 72
Gap between the floor and skirting
Issue number: 73
Light not work correctly
Issue number: 74
Poor standard of plastering, generally
Issue number: 75
Paint on door handle
Issue number: 76
Poor paint finish to door lining, paint missing between hinges and architrave
Issue number: 77
Paint on light switch
Issue number: 78
Vanity light transformer left in draw
Issue number: 79
Towel radiator brackets upside down
Issue number: 80
Toilet cistern not back to the wall.
Issue number: 81
Images of both poor finish to the joinery and paintwrk to the door lining
Issue number: 82
Issue number: 83
Intumescent strip missing to door lining
Issue number: 84
Incorrect screws in door hinge
Issue number: 85
Rough cut out for door latch
Issue number: 86
No lagging on heating/ hot water pipes
Issue number: 87
Hot water cylinder base, poorly constructed out rough timber
Issue number: 88
Rough cut out to cupboard for boiler flue
Issue number: 89
Skirting mitre not lining up
Issue number: 90
Cable not cabled or placed in trunking



Issue number: 91
Butt joint to skirting, clearly visible


Issue number: 92
Generally poor finish to skirting, lining below fireplace


Issue number: 93
cover missing from light switch