Issue number: 1
System is fitted with a pressurised hot water cylinder that needs 3bar of incoming water pressure, the incoming main is only 2.5bar of pressure
Issue number: 2
The system needs a secondary return, as the furthest hot tap is over 12m from the cylinder.
There is a pipe connected to the secondary return connection on the cylinder, but there is no pump or check value
Issue number: 3
Magnetic filter has been fitted to the return to the cylinder and not the heating system
Issue number: 4
The expansion vessel incorrectly fitted to the secondary return on the cylinder
Issue number: 5
There are some cold spots on the floor, would recommand having a thermal imaging firm in to detamin the routes of the pipes
Issue number: 6
Check values have not been fitted
Issue number: 7
Pipes have not been insulated.
Traps have not been fitted to the wastes within the garage